B–63130EN/01
1. PARAMETERS OF THE PRESS FUNCTION
1
1
PARAMETERS OF THE PRESS FUNCTION
#7 #6 #5 #4 #3 #2 #1 #0Address
16000 PEI NFI PFI RPF HCI HSP
Data type: Bit
HSP High–speed press control is:
0: Disabled.
1: Enabled.
The following functions cannot be used:
S Servo waveform display (The correct waveform
cannot be displayed while this function is being used.)
S Axis control by PMC (PMC axis cannot be controlled
while this function is being used)
S Look–ahead control
HCI Under high–speed press control, the *PFIN signal to complete
punching for single–cycle pressing, and the *NFIN signal to
complete punching for continuous pressing are valid for:
0: Standard address (X1004).
When this is selected, the maximum stop time, from
when the punching complete signal is input until
movement along an axis starts, is 5 msec.
1: High–speed DI address HDI0 (both *PFIN and *NFIN).
When this is selected, the maximum stop time, from
when the punching complete signal is input until
movement along an axis starts, is 3 msec. To enable the
use of this parameter, the high–speed DI is necessary.
When the high–speed DI is used, set parameter
No.6207#0 (IOC) to 1.
RPF When the RESET key is pressed or when external reset, reset
and rewind, or emergency stop is activated, the PF signal to start
pressing is:
0: Set to 0.
1: Not set to 0.
PF is set to 0 only when the *PE signal to stop pressing is
set to 0.
PFI The logic of the *PFIN signal to complete punching for
single–cycle pressing is:
0: The same as the logic described in the ”Connection
Manual.”
1: The reverse of the logic described in the ”Connection
Manual.”
1. PARAMETERS OF THE PRESS FUNCTION
B–63130EN/01
2
NFI The logic of the *NFIN signal to complete punching for
continuous pressing is:
0: The same as the logic described in the “Connection
Manual.”
1: The reverse of the logic described in the “Connection
Manual.”
PEI The logic of the *PE signal to stop pressing is:
0: The same as the logic described in the “Connection
Manual.”
1: The revese of the logic described in the “Connection
Manual.”
#7 #6 #5 #4 #3 #2 #1 #0Address
16001 CPF MPF PMA PSY PE2 PRC PFE MNP
Data type: Bit
MNP If there remains a distance to be traveled when automatic
operation is halted, manual pressing or continuous manual
pressing is:
0: Validated.
1: Invalidated.
PFE When the PF signal to start pressing is set to 1, the absolute
value of positional deviation for the X– and Y– axes:
0: Must be less than or equal to the value set in paramter
1610.
1: Need not be less than or equal to the value set in parameter
1610.
PRC When the machine lock signal, MLK, is set to 1, a program
check is:
0: Not executed.
1: Executed.
The machine position data is updated although the actual
position is not changed. This setting is invalid for the
machine lock signal of each axis.
PE2 To output the PF signal to start pressing, position check is
executed at intervals of:
0: 8 msec.
1: 2 msec.
PSY Under simple synchronous control, the PF signal to start
pressing is output:
0: Irrespective of the machine coordinates of the
synchronous axes.
1: After it has been confirmed that the machine coordinates
of the synchronous axes agree with each other. If the
machine coordinates differ, alarm 213 will be issued and
the PF signal will not be output.
PMA When the AFL signal to lock miscellaneous functions is set to
1, M code signals for forming, repositioning, and nibbling are:
0: Not output to the machine.
1: Output to the machine.
B–63130EN/01
1. PARAMETERS OF THE PRESS FUNCTION
3
MPF In a block containing an M code, the PF signal to start pressing
is:
0: Not set to 1.
1: Set to 1.
PF is set to 1 when movement along an axis terminates or
when completion of the miscellaneous function is
returned.
CPF At the end of the 01 group containing the G01, G02, or G03
code, the PF signal to start pressing is:
0: Not set to 1.
1: Set to 1.
#7 #6 #5 #4 #3 #2 #1 #0Address
16002 EUP PF9 PWB SPR PFB PEM NIP
Data type: Bit
NIP Upon the completion of punching, ITP shift is:
0: Performed (The delay between the completion of punching
and the start of axial movement is fixed to 19 ms.)
1: Not performed (The delay between the completion of
punching and the start of axial movement varies within a
range of 11 to 19 ms.)
PEM MDI operation:
0: Does not start pressing.
1: Starts pressing.
PFB The PFB signal to start pressing is:
0: Enabled.
1: Disabled.
SPR The *SPR signal to halt automatic oparation B is:
0: Invalidated.
1: Validated.
PWB The PFWB signal to wait for the start of pressing B is:
0: Invalidated.
1: Validated.
PF9 The time interval between setting of the PFB signal to start
pressing B to 0 and setting of the PF signal to start pressing to
0 is set to the value in:
0: Parameter 16037.
1: Parameter 16038.
EUP By executing the external operation function, the number of
punching cycles is:
0: Not aggregated.
1: Aggregated.
One is added when the PF signal to start pressing and the
EF signal to external operation are set to 1.
1. PARAMETERS OF THE PRESS FUNCTION
B–63130EN/01
4
#7 #6 #5 #4 #3 #2 #1 #0Address
16003 NED DPE TCF
Data type: Bit
TCF After the OP signal indicating that automatic operation is in
progress is set from 0 to 1, the PF signal to start pressing is set
to 1:
0: Only when a T command is found.
This status is the same as the status in which the PFW
signal to wait for the start of pressingis set to 1.
1: Even if no T commands are found.
DPE The relationship between the *PE signal to stop pressing and the
EPE signal for ignoring the signal to stop pressing is as follows:
0: *PE is always validated irrespective of the status of EPE.
1: *PE is validated when EPE is set to 1, and invalidated
when EPE is set to 0.
NED After the last positioning ends in a nibbling block, the PF signal
to start pressing is set to 0:
0: When the contact of the *PE signal to stop pressing is set
to 0.
1: When the two contacts of the *NFIN signal to complete
punching for continuous pressing and the *PE signal stop
pressing are set to 0.
Address
16008 M code for setting the forming mode
16009 M code for canceling the forming mode
Data type: Byte
Valid data range: 1 to 97
Parameter 16008 sets the M code for setting the forming mode.
Parameter 16009 sets the M code for canceling the forming mode.
Address
16010 Upper limit of the position deviation at which PF is set to 1
Data type: Word axis
Unit of data: Units of detection
Valid data range: 0 to 32767
For each axis, parameter 16010 sets the upper limit of the positional
deviation at which the PF signal to start pressing is set to 1. When the
absolute value of the positional deviation does not exceed this highest
limit, PF is set to 1.
Parameter 16010 is validated when parameter PFE (No. 16001, #1) is set
to 1.
NOTE
The parameter can only be set for the X, Y, and C axes.
B–63130EN/01
1. PARAMETERS OF THE PRESS FUNCTION
5
Address
16011 Duration for which the start of positioning is delayed
Data type: Byte axis
Unit of data: msec
Valid data range: 0 to 248
For each axis, parameter 16011 sets the duration for which the start of
positioning is delayed.
NOTE
1 Only a multiple of 8 can be set for parameter 16011.
2 The parameter can only be set for the X, Y, and C axes.
Positioning
Time set in parameter 16011
Positioning in the
next block
Address
16012 Time interval by which setting of PF to 1 precedes completion of positioning
Data type: Byte axis
Unit of data: msec
Valid data range: 0 to 248
For each axis, parameter 16012 sets the time interval by which setting of
the PF signal to start pressing to 1 precedes completion of positioning.
(Function to advance setting of the PF signal)
NOTE
1 When parameter KLV (No. 16050, #7) is set to 1, the data
is invalidated. If it is invalidated, see the descriptions of
parameters 16–13 to 16026.
2 The parameter can only be set for the X, T, and C axes.
1. PARAMETERS OF THE PRESS FUNCTION
B–63130EN/01
6
Address
16013
Time interval by which setting of PF to 1 precedes completion of X–axis
positioning for the distance of level 1
16014
Time interval by which setting of PF to 1 precedes completion of X–axis
positioning for the distance of level 2
16015
Time interval by which setting of PF to 1 precedes completion of X–axis
positioning for the distance of level 3
16016
Time interval by which setting of PF to 1 precedes completion of X–axis
positioning for the distance of level 4
16017
Time interval by which setting of PF to 1 precedes completion of X–axis
positioning for the distance of level 5
16018
Time interval by which setting of PF to 1 precedes completion of X–axis
positioning for the distance of level 6
16019
Time interval by which setting of PF to 1 precedes completion of X–axis
positioning for the distance of level 7
Data type: Byte
Unit of data: msec
Valid data range: 0 to 120
Each of these parameters set the time interval by which setting of the PF
signal to start pressing to 1 precedes completion of X–axis positioning for
the corresponding distance level. (Function to advance setting of PF
signal)
The parameters are validated when parameter KLV (No. 16050, #7) is set
to 1.
For the positioning distance, see the descriptions of parameters 16055 to
16066.
Address
16020
Time interval by which setting of PF to 1 precedes completion of Y–axis
positioning for the distance of level 1.
16021
Time interval by which setting of PF to 1 precedes completion of Y–axis
positioning for the distance of level 2.
16022
Time interval by which setting of PF to 1 precedes completion of Y–axis
positioning for the distance of level 3.
16023
Time interval by which setting of PF to 1 precedes completion of Y–axis
positioning for the distance of level 4.
16024
Time interval by which setting of PF to 1 precedes completion of Y–axis
positioning for the distance of level 5.
16025
Time interval by which setting of PF to 1 precedes completion of Y–axis
positioning for the distance of level 6.
16026
Time interval by which setting of PF to 1 precedes completion of Y–axis
positioning for the distance of level 7.
Data type: Byte
Unit of data: msec
Valid data range: 0 to 120
B–63130EN/01
1. PARAMETERS OF THE PRESS FUNCTION
7
Each of these parameters set the time interval by which setting of the PF
signal to start pressing to 1 precedes completion of Y–axis positioning for
the corresponding distance level. (Function to advance setting of PF
signal)
The parameters are validated when parameter KLV (No. 16050, #7) is set
to 1.
For the positioning distance, set the descriptions of data 16055 to 16066.
Address
16027
Time interval by which setting of PF to 1 precedes completion of C–axis
positioning for the distance of level 1.
16028
Time interval by which setting of PF to 2 precedes completion of C–axis
positioning for the distance of level 2.
16029
Time interval by which setting of PF to 3 precedes completion of C–axis
positioning for the distance of level 3.
Data type: Byte
Unit of data: msec
Valid data range: 0 to 120
Each of these parameters set the time intarval by which setting of the PF
signal to start pressing to 1 precedes completion of C–axis positioning for
the corresponding distance level. (Function to advance setting of PF
signal)
The parameters are validated when parameter KLC (No. 16050, #4) is set
to 1.
For the positioning distance, see the description of data 16140 and 16141.
Positioning
Time set in the parameter
PF
(Function to advance setting of PF signal)
If the time set here is longer than the time required for deceleration, the
PF signal is set to1 when decelaration starts.
In simultaneous positioning for the X, Y, and C axes, the PF signal is set
to 1 when the individual conditions for the X, Y, and C axes are all
satisfied.
1. PARAMETERS OF THE PRESS FUNCTION
B–63130EN/01
8
C–axis
positioning
Time set for the C–axis
X–axis
positioning
Y–axis
positioning
Time set for the Y–axis
Time set for the X–axis
PF
Address
16030
Time interval by which setting PF to 0 follows setting *PE to 0 in single–
cycle pressing
Data type: Byte
Unit of data: msec
Valid data range: 0 to 248
Parameter 16030 sets the time interval by which setting the PF signal to
start pressing to 0 follows setting the contact of the *PE signal to stop
pressing to 0 in single–cycle pressing.
Address
16031
Time interval between completion of positioning and the start of the next
block when PFL is set to 1
Data type: Byte
Unit of data: msec
Valid data range: 0 to 248
Parameter 16031 sets the time interval between completion of positioning
and the start of the next block when are PFL signal to lock the start of
pressing is set to 1.
Address
16032
Time interval by which setting of PF to 1 follows positioning in the forming
mode
Data type: Byte
Unit of data: msec
Valid data range: 0 to 248
Parameter 16032 sets the time interval by which setting the PF signal to
start pressing to 1 follows positioning in the forming mode (except for
nibbling).
B–63130EN/01
1. PARAMETERS OF THE PRESS FUNCTION
9
Address
16033
Time interval by which the start of the next bolck follows setting of *PFIN to
0 in the forming mode
Data type: Byte
Unit of data: msec
Valid data range: 0 to 248
Parameter 16033 sets the time interval by which the start of the next block
follows setting the contact of the *PFIN signal to complete punching for
single–cycle pressing to 0 in the forming mode.
Positioning
Time set in
parameter
16032
Next block
Time set in
parameter
16033
PF
*PFIN
Address
16034 Time interval by which setting PF to 1 follows first positioning in nibbling
Data type: Byte
Unit of data: msec
Valid data range: 0 to 248
Parameter 16034 sets the time interval by which setting the PF signal to
start pressing to 1 follows positioning at the first punch point in nibbling
(nibbling by G68, G69, and M code).
Address
16035
Time interval by which the start of the next block follows setting *NFIN to 0
at the last positioning in nibbling
Data type: Byte
Unit of data: msec
Valid data range: 0 to 248
Parameter 16035 sets the time interval by which the start of the next block
follows setting the contact of the *NFIN signal to complete punching for
continuous pressing to 0 at positioning at the last punch point in nibbling
(nibbling by G68, G69, and M code).
1. PARAMETERS OF THE PRESS FUNCTION
B–63130EN/01
10
Address
16036
Minimum time interval by which setting of PF to 1 follows setting of *PFIN
to 0 in single–cycle pressing
Data type: Byte
Unit of data: msec
Valid data range: 0 to 248
Parameter 16036 sets the minimum time interval by which setting the PF
signal to start pressingto 1 follows setting the contact of the *PFIN signal
to complete punching for single–cycle pressing to 0 in single–cycle
pressing. After the contact of *PFIN is set to 0, PF is set to 1 when the time
set here elapses. PF is not set to 1 even if positioning for the next block
completes and other conditions are satisfied before the time elapses.
Address
16037
Time interval by which setting PFB to 1 follows setting PF to 1 and settiug
PF to 0 follows setting PFB to 0
Data type: Byte
Unit of data: msec
Valid data range: 0 to 20
Parameter 16037 sets the time interval by which setting the PFB signal
to start pressing B to 1follows setting the PF signal to start pressing to 1
and setting PF to 0 follows setting PFB to 0.
NOTE
1 Only a multiple of 2 can be set for parameter 16037.
2 The parameter must be set to 0 when the PFB signal is not
used.
PF
PFB
*PE
Time set in
parameter
16037
Time set in
parameter
16030
Time set in
parameter
16037
Address
16038 Time interval by which setting PF to 0 follows setting PFB to 0
Data type: Byte
Unit of data: msec
Valid data range: 0 to 20
Parameter 16038 sets the time interval by which setting the PF signal to
start pressing to 0 follows setting the PFB signal to start pressing B to 0.
The data is validated when parameter PF9 (No. 16002, #6) is set to 1.